IDEC WinLDR installation instructions

Note IP Address of PLC

The IP Address can be found in the network settings tab. If this is not already set, give it an IP address that hasn't already been taken by the network. E.g. 192.168.1.5

Network Settings-1

Setup Modbus Server

Navigate to Connection Settings. Create a modbus TCP Server (Slave)

Connection Settings-1

Configure Modbus

The default settings will work for this. If the port number is different, let us know and we can set this on the PLAATO portal.

Configure Modbus-1

Export the Tag values

  • Navigate to the Tag Editor. Select "All Addresses" (or only the tags that you'd like to monitor).
  • Press the export button (Ctrl+E)

Tag Editor-1

Then save the exported file and send it to support@plaato.io, or your customer success manager. 